Search results for "quadrupole mass spectrometer"
showing 10 items of 37 documents
Determination of type A and type B trichothecenes in paprika and chili pepper using LC-triple quadrupole-MS and GC-ECD.
2011
There is a need to develop sensitive and accurate analytical methods for determining deoxynivalenol (DON), HT-2 toxin and T-2 toxin in paprika to properly assess the relevant risk of human exposure. An optimized analytical method for determination of HT-2 toxin and T-2 toxin using capillary gas chromatography with electron capture detection and another method for determination of DON by liquid chromatography-mass spectrometry in paprika was developed. The method for determination of HT-2 toxin and T-2 toxin that gave the best recoveries involved extraction of the sample with acetonitrile-water (84:16, v/v), clean-up by solid-phase extraction on a cartridge made of different sorbent material…
Optimization of LC–MS/MS using triple quadrupole mass analyzer for the simultaneous analysis of carbosulfan and its main metabolites in oranges
2006
This paper describes an analytical method involving a simple solvent extraction for the simultaneous liquid chromatography coupled to quadrupole tandem mass spectrometry (LC-MS/MS) determination of carbosulfan, its most toxic metabolite--carbofuran--, and its other main metabolites--3-hydroxycarbofuran, 3-ketocarbofuran, 3-hydroxy-7-phenolcarbofuran, 3-keto-7-phenolcarbofuran, 7-phenolcarbofuran and dibutylamine--in oranges. Chromatography was performed on a Zorbax Bonus-RP (150 mm x 2.1 mm, 5 microm). The mobile phase was a ternary gradient water-methanol-acetonitrile with 1.0 mM ammonium acetate at flow rate of 0.2 ml min(-1). The LC separation and MS/MS optimization were studied to selec…
Nuts and dried fruits: Natural occurrence of emerging Fusarium mycotoxins
2013
Abstract The occurrence of enniatins (ENs) and beauvericin (BEA) in nuts, dried fruits and dates available in Valencia (Spain) was surveyed in this study. To do this, seventy-four samples of nuts, dried fruits and dates were analyzed for the determination of mycotoxin contamination. Mycotoxins were identified and quantified using an ultrasonic-C18 extraction and LC–MS/MS with a triple quadrupole (QqQ) mass analyzer. The frequencies of contamination of nuts, shell, dried fruits and dates were 50%, 80%, 35.7% and 83.3%, respectively. Enniatin A (ENA) was the most predominant EN found in nuts (45.2%) while ENB was the most common EN found in dates (58.3%). The analytical results of the shell s…
Development of a new multi-analyte assay for the simultaneous detection of opioids in serum and other body fluids using liquid chromatography-tandem …
2015
Abstract A liquid chromatography–tandem mass spectrometry method using electrospray ionization in positive ionization mode was developed for the simultaneous detection of multiple opioid-type drugs in plasma. The presented assay allows the quantitative determination of alfentanil, buprenorphine, codeine, desomorphine, dextromethorphan, dextrorphan, dihydrocodeine, dihydromorphine, ethylmorphine, fentanyl, hydrocodone, hydromorphone, methadone, morphine, naloxone, naltrexone, oxycodone, oxymorphone, pentazocine, pethidine, pholcodine, piritramide, remifentanil, sufentanil, and tramadol as well as the metabolites 6-monoacetylmorphine, bisnortilidine, morphine-3-glucuronide, morphine-6-glucuro…
Distribution and fate of perfluoroalkyl substances in Mediterranean Spanish sewage treatment plants.
2014
The concentrations of 21 perfluoroalkyl substances (PFASs: C4-C14, C16, C18 carboxylates, C4, C6-C8 and C10 sulfonates and C8 sulfonamide) were determined in influent, effluent and sludge from 16 different sewage treatment plants (STPs) located in the Ebro (6), Guadalquivir (5), Jucar (2) and Llobregat (3) Rivers, in two consecutive years (2010 and 2011). The analytes were extracted by solid phase extraction (SPE) and determined by Liquid Chromatography triple Quadrupole Mass Spectrometer (LC-QqQ-MS). All samples, except two sludges from Guadalquivir River STPs, were contaminated with at least one PFAS. Perfluorobutanoate (PFBA), perfluoropentanoate (PFPeA) and perfluorooctane sulfonate (L-…
A reliable screening of mycotoxins and pesticide residues in paprika using ultra-high performance liquid chromatography coupled to high resolution Or…
2016
Abstract In this study, an ultra-high performance liquid chromatography (UHPLC) coupled to a high resolution Orbitrap mass spectrometry (Orbitrap-HRMS) was demonstrated as a promising technique in high-throughput method development for the routine analysis and contamination control of mycotoxins and pesticide residues in spices. The method was applied for the analysis of fifty ground paprika samples containing blends of sweet and hot paprika harvested in Brazil and China. The efficiency and detection sensitivity of the used UHPLC-Orbitrap-HRMS technique were compared to the results obtained using a triple quadrupole tandem mass spectrometric detector (UHPLC-QqQ-MS/MS). The values of recover…
The application of phospholipid removal columns and ultra-high performance liquid chromatography-tandem quadrupole mass spectrometry for quantificati…
2016
In this study a robust and sensitive method based on a proposed sample purification procedure, using zirconia-coated Phree™ columns and analysis by ultra-high performance liquid chromatography with triple quadrupole tandem mass spectrometry are presented for the assessment of multi-class antibiotics in farmed fish species. The sample preparation procedure benefited from combined precipitation of proteins and selective removal of phospholipids by Phree™ columns, resulting in a high sensitivity of the method (LOQ 0.3-9mgkg(-1)). The in-house validation results (precision, repeatability, decision limit CCα, detection capability CCβ, etc.) indicate that the elaborated method is fully suitable f…
Kompakti automatisoitu laser-ionisointijärjestelmä
2011
In an experimental nuclear physics off-line systems are often used in situations where acceleration energies are relatively small. Main benefits are low price and meager radiated laboratory enviroments. In this master’s thesis I discuss mostly about automation which was used in our off-line system. The system was built at the Ion Guide Separator On-Line facility (IGISOL) in Jyväskylä University. The automation set up was made with the Phoenix Contacts inline terminals, which were programmed by using the Labview program. The system consists of thermistor, skimmer handling, mirror handling, gasline parts per billion (ppb) mixing and quadrupole mass spectrometer measurement. There were major p…
Combined use of liquid chromatography triple quadrupole mass spectrometry and liquid chromatography quadrupole time-of-flight mass spectrometry in sy…
2012
As a suitable way for routine screening of pesticides and control of other organic contaminants in water, the combination of liquid chromatography triple quadrupole tandem mass spectrometry (LC-QqQ-MS/MS) and liquid chromatography-hybrid quadrupole time-of-flight mass spectrometry (LC-QTOF-MS) has been applied to the analysis of 63 surface and waste water samples after conventional solid-phase extraction (SPE). The extracts were screened for 43 pesticides or degradation products by LC-QqQ-MS/MS achieving limits of detection (LOD) ranged from 0.04 to 2 ng L(-1). Of the 43 selected pesticides, 33 were detected in water samples. The ESI-QTOF MS instrument was run using two simultaneous acquisi…
The Use of Chromatographic Methods Coupled to Mass Spectrometry for the Study of Emerging Pollutants in the Environment.
2018
The consumption of compounds that improve the human health and wellness is increasing, and as a result, the residues of these substances reach the environment or food chain. For this reason, the scientific community is looking for new analytical methods that are more accurate and can detect the greatest number of compounds in different matrices. This manuscript compares different studies in abiotic and biotic matrices, where most of them (92%) uses Liquid Chromatography to separate the compounds. For the detection, most of the studies for both matrices uses, coupled to the chromatograph, a triple quadrupole mass spectrometer (50%) due to the precision to quantify the concentration of these …